ISOVER OL-33 Façade
The product is suitable for insulating sandwich panels both in the factory and on the construction site. OL-33 Facade can also be used for insulating solid structures that are brick-built on site. The boards are coated with a wind-barrier surface, which provides good protection against wind and moisture while allowing any moisture within the insulation to dry out efficiently.
When using OL-33 Facade, the joints and connection points of the boards must be sealed/taped with ISOVER KB3 joint tape. Vertical and horizontal joints can be taped with 60 mm wide tape. For panel connection joints, a 90 mm wide tape is recommended. The taping conditions should be as optimal as possible — the minimum temperature is −5°C, and the surfaces must be dry and dust-free. For the connection joints of elements, ISOVER KH joint strip must be used to ensure tight and thermal-bridge-free connections.
For more information: https://www.isover.fi/
| Registration number | EPD-IES-0027492:001 |
|---|---|
| Status | Valid |
| Version date | 2026-02-06 |
| Validity date | 2031-02-06 |
| PCR | 2019:14 Construction products (EN 15804+A2) (version 2.0.1) 2.0.1 |
| c-PCR | 2019:14-c-PCR-005 Thermal insulation products (EN 16783) (c-PCR to PCR 2019:14) 1.0.0 |
| Standards conformance | ISO 14025:2006, EN 15804:2012+A2:2019/AC:2021 |
| Geographical scope | Estonia, Latvia, Finland, Lithuania |
| LCA Practitioners | Edward Hsu, Edward.Hsu@Saint-Gobain.com, Saint-Gobain Finland Oy |